Door Controller CardsAdvantages of Using KM 10 System
Full Domination
Motor Domination
The KM-10 door control card provides full control of the motor with 4 zone motor control and dual channel high resolution encoder input as hardware
Door Movements
Serial and Smooth
The advanced software softens the S in the navigation ramps and permits serial but smooth movements of the door movements with no limit switch-free algorithm
Automatic Door Status Detection
No Limit Switches Required
The door operator does not need a limit switch for operation. Door width, door open-close positions are detected automatically
Power Interruption
Battery and DC Supply
It can work with 2 12V battery supply or 24VDC external power supply
Battery Check
Card Support
The acupuncture is made by the card. After emergency door opening with battery support, the card will go to sleep, preventing the discharge of the pacemakers completely
Closed Doors Up to Floor Level
Battery Charging System
If the elevator is not in the door opening area with the floor signal, it is ensured that the doors are kept closed to the level of the floor in the cordless crawler systems
Possible Door Jam
When the door is jammed, the buzzer is turned back on. The jamming is passed slowly through the perceived zone to prevent damage to the passengers and the door
Access to the Menu
Authorization
In terms of security, necessary needs and ease of setup, access to the menu has been authorized. Different levels of authority have been assigned to access the menu: producer level, basic level and restricted level
Application Flexibility
Wide Parameter Capability
For manufacturers, parameters such as motor reduction ratio, engine revolutions, drive pulley circumference, spoon opening zone, etc. can be entered for application flexibility
User Settings
For user settings, defined speed settings in centimeters per second and defined ramp paths in centimeters can be specified
Pressure Settings
Variability According to Need
Door open and closed holding pressure, door jam detection can be adjusted according to the need of the press
Door Operation Attachment
Counter Support
Operation of the door can be monitored by the on / off counter
Other Specifications
Motor Tipi | 24V Redüktörlü DC Motor |
Motor Çıkış Gücü | Maks. 200W (8A) |
Motor Kontrol Şekli | 4 Bölge Kontrol |
Motor Koruması | Aşırı Yük ve Kısa Devre Korumalı |
Enkoder Tipi | 2 Kanal İnkremental (Artımlı) Enkoder (Tek kanal enkoder ile çalıştırılamaz) |
Enkoder Voltajı | 5 VDC |
Çözünürlüğü | 100-2048 pals Arasında Herhangi Bir Model |
Akü Beslemesi ve Şarjı | 2 Adet 12V/1.2Ah Akü / Dahili Şarj Var |
Akü Koruması | Sigorta Koruması (5A) |
Kapı Genişliği ve Hızı | 50 cm - 300 cm / Maks. 50 cm/s |
- Door fully open / fully closed
- Door jam or photocell active output
- Relay contact output. For 3A, 250VAC or 30VDC
- Door open / close signal
- Slow signal / fast signal
- Photocell signal
- Ground signal
- Active with 24VDC
- Suitable for use on fire lift doors (High speed signal input can be detected)