4.png
3.png
1.png

KM 10S

Door Controller Cards

Input Supply Voltage
20VAC±%10
Maximum Power Consumption
10W (Control Circuit) + Motor power
Feed Protection
Fuse Protected (8A)
Language Options
Turkish, English and Greek
Standard Interface
2 Rows, 16 Character LCD display, 4-Button Button Kit
Audible Warning
With the Buzzer
Dimensions (mm)
116 x 160 x 50 (Width x Length x Height)
Other
Detailed Setting and Status Monitoring with 1 Piece of Programmable Input Integrated Keypad LCD display

Advantages of Using KM 10 System

Full Domination

Motor Domination

The KM-10 door control card provides full control of the motor with 4 zone motor control and dual channel high resolution encoder input as hardware

Door Movements

Serial and Smooth

The advanced software softens the S in the navigation ramps and permits serial but smooth movements of the door movements with no limit switch-free algorithm

Automatic Door Status Detection

No Limit Switches Required

The door operator does not need a limit switch for operation. Door width, door open-close positions are detected automatically

Power Interruption

Battery and DC Supply

It can work with 2 12V battery supply or 24VDC external power supply

Battery Check

Card Support

The acupuncture is made by the card. After emergency door opening with battery support, the card will go to sleep, preventing the discharge of the pacemakers completely

Closed Doors Up to Floor Level

Battery Charging System

If the elevator is not in the door opening area with the floor signal, it is ensured that the doors are kept closed to the level of the floor in the cordless crawler systems

Possible Door Jam

When the door is jammed, the buzzer is turned back on. The jamming is passed slowly through the perceived zone to prevent damage to the passengers and the door

Access to the Menu

Authorization

In terms of security, necessary needs and ease of setup, access to the menu has been authorized. Different levels of authority have been assigned to access the menu: producer level, basic level and restricted level

Application Flexibility

Wide Parameter Capability

For manufacturers, parameters such as motor reduction ratio, engine revolutions, drive pulley circumference, spoon opening zone, etc. can be entered for application flexibility

User Settings

For user settings, defined speed settings in centimeters per second and defined ramp paths in centimeters can be specified

Pressure Settings

Variability According to Need

Door open and closed holding pressure, door jam detection can be adjusted according to the need of the press

Door Operation Attachment

Counter Support

Operation of the door can be monitored by the on / off counter

Other Specifications

 

Motor Tipi 24V Redüktörlü DC Motor
Motor Çıkış Gücü Maks. 200W (8A)
Motor Kontrol Şekli 4 Bölge Kontrol
Motor Koruması Aşırı Yük ve Kısa Devre Korumalı
Enkoder Tipi 2 Kanal İnkremental (Artımlı) Enkoder (Tek kanal enkoder ile çalıştırılamaz)
Enkoder Voltajı 5 VDC
Çözünürlüğü 100-2048 pals Arasında Herhangi Bir Model
Akü Beslemesi ve Şarjı 2 Adet 12V/1.2Ah Akü / Dahili Şarj Var
Akü Koruması Sigorta Koruması (5A)
Kapı Genişliği ve Hızı 50 cm - 300 cm / Maks. 50 cm/s
  • Door fully open / fully closed
  • Door jam or photocell active output
  • Relay contact output. For 3A, 250VAC or 30VDC
  • Door open / close signal
  • Slow signal / fast signal
  • Photocell signal
  • Ground signal
  • Active with 24VDC
  • Suitable for use on fire lift doors (High speed signal input can be detected)